The spring torque tester is suitable for testing torsion angle and torsion torque of torsion springs, worm springs, elastic elements and friction mechanisms. Torsional tests can be performed on parts and components by adding corresponding accessories. This machine complies with the "GB/T9370-1999" and "JJG269-1981" torsion test machine standards and material testing methods. How much do you know about the spring torque test machine? Let me take a look at the common key instructions and taboos of the spring torque test machine with the editor.

Common key instructions and taboos for spring torque testing machines

1. Common keys for spring torque testing machines

1.ON/OFF key: can be used to turn on and off;

2. Angle clear key: During real-time measurement, press this key to correct the angle zero point;

3. View key of the spring torque test machine: This key can be used to view the stored measurement data during the measurement interface;

4. Clear key: During real-time measurement, press this key to correct the torque zero point. During peak and automatic peaks, press this key to clear the peak and return to zero; when viewing the interface, press this key to clear the current stored measurement value, and press this key to clear all stored measurement values. In the user settings interface, press this key to not save data and return to the previous interface;

5. Peak key: used to switch three measurement modes: real-time, peak, and automatic peak during the measurement interface, and has an upward shift function in the setting interface. In the viewing interface, press this key to view the previous data;

6. Save key of the spring torque tester: It is used to save the measured data during the measurement interface, and has a downward movement function in the setting interface. In the viewing interface, press this key to view the next data;

7. Print key: On the measurement interface, press this key to print the stored measurement value. There is a left-shift function in the setting interface;

8. Unit key: used to switch between N·m, kgf·cm, and Ib·in when measuring interface. There is a right-shift function in the setting interface;

9. Setting key of the spring torque tester: The user can enter the setting menu through this key in the measurement interface, and press this key to save the data when setting the data.

Common key instructions and taboos for spring torque testing machines

2. Taboos of spring torque test machine

1. Do not overload test torque. Be sure to test torque within the test range of the torque tester, otherwise it will damage the instrument and may cause danger;

2. Do not tap the LCD screen and place the object on the LCD screen;

3. Do not press the function keys with nails, sharp tools or pointed objects;

4. Do not use the torque tester where water, oil or other liquids are splashed. Store the torque tester in a cool, dry and vibration-free place;

5. Do not loosen the fixing screws of the torque test head.

Mechanical equipment is essentially the same. The coordinated operation of different components can only make the entire experimental process smoother and the experimental data more accurate. The above is the common key instructions for spring torque testing machines and the related introduction to taboos. I hope it can help you.