Hello, welcome to visitJinan Hengsi Shanda Instrument Co., Ltd.
Some of you are interested in:
Current location:front page >> News >> Company News

Company News

Problems that may arise when placing the material tester binning when participating in control

Release time:2018-11-23 source:Jinan Hengsi Shanda Instrument Co., Ltd. Browse:


Material testing machineDuring the grading process, some problems often occur in the test machine during the control operation, which makes it difficult to use during the machine test operation.
At present, due to the diversification of materials, more and more test methods are required, and more and more requirements for the control method of the test machine. For example: polymer materials needTesting machineFor speed control, building materials require load control, metal materials require load or deformation control, building components may require acceleration control, etc. From the automatic control theory, if the parameters of any link within a closed-loop system change, it will cause the working state of the entire closed-loop system to change, causing the system to fail to work normally. In order to enable the system to work stably, some control parameters (usually P.I.D parameters) need to be adjusted in time. Shifting is to change the amplification ratio of the amplifier inside the closed-loop system, which will inevitably lead to changes in the working state of the entire system. That is to say, after shifting gears, you must switch the P.I.D parameters to a value that is suitable for the current gear. But the problem is that in addition to gear position, this parameter value is also related to the sample, and the sample is ever-changing and different, so its specific magnitude cannot be determined in advance; in addition, control fluctuations will occur when shifting gears, which will have an impact on the test results. In the past, since high A/D was not available, data acquisition was the main contradiction, so grading was still used on multi-closed-loop test machines. But it is generally only divided into three levels, and it is very troublesome to use. Now, the problem of high-level A/D has been solved, and easy use has become a problem to be considered. Therefore, generally speaking, non-stage technology is basically adopted in multi-closed-loop testing machines.
MoreMaterial testing machineTechnical articles are all available at: Jinan Hengsi Shanda Instrument Network
Tag: Universal Testing Machine, hydraulic universal testing machine, tensile testing machine, impact tester, twisting test machine, Material Testing Machine