Hello, welcome to visitJinan Hengsi Shanda Instrument Co., Ltd.
Some of you are interested in:

Reckhee hardness meter HSL5300

Reckhee hardness meter HSL5300

Reckhee hardness meter HSL5300

Product Classification: Hardness meter series
Product Overview:Richmond hardness meter measurement materials: steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper-zinc alloy (brass), copper-tin alloy (bronze), pure copper, forged steel and other materials.

Measuring materials: hardness measurement of steel and cast steel, alloy tool steel, stainless steel, grey cast iron, ductile iron, cast aluminum alloy, copper-zinc alloy (brass), copper-tin alloy (bronze), pure copper, forged steel and other materials.

Unique features: equipped with high-precision D-type sensor, with support frame, high-brightness large screen, and no viewing angle.

Portable Richmond hardness meter Main uses:

u The machining industry is particularly suitable for on-site hardness testing of large parts and non-detachable parts

u Installed mechanical or permanent assembly parts hardness.

u Mold cavity hardness.

u Heavy duty workpiece hardness

u Failure analysis of pressure vessels, steam turbine generator sets and their equipment

u The hardness of the workpiece with a very small experimental space

u Hardness of bearings and other parts

u Material distinction of metal material warehouses

u Rapid detection of multiple measurement parts in large-scale workpieces

Portable Richmond hardness meter Functional features:

u Design basis standards: "Technical Conditions of Richmond Hardness Meters" JB/T 9378-2001; adopts D-type high-precision impact device;

u Industrial housing design, sturdy, compact, portable, high reliability, suitable for harsh operating environments, resistant to vibration, impact and electromagnetic interference;

u The integrated design of the host and printer is convenient for users to print test results on-site;

u Large-screen OLED 128×64 dot matrix display, rich in information and intuitive. No blind spots, convenient for operation and reading;

u Seven hardness values ​​such as Shore (HS), Richter (HL), Brecht (HB), Rockwell (HRC/HRB/HRA), Vickers (HV) can be measured at one time and automatically converted;

u Large-capacity nickel-hydrogen rechargeable battery and charging control circuit, residual power indication icon, charging process indication, you can understand the charging degree at any time;

u It has the function of calibration of the startup display software to ensure that the data is applicable and accurate under different specifications and standards in any industry;

u 7 different impact devices can be optionally equipped, no calibration is required during replacement, and automatic identification is required;

u You can set upper limit lower value and over limit alarm in advance;

u It can store 600 sets of measured values ​​and all menus, backlight display, and convenient operation;

u It can be equipped with powerful microcomputer software, with rich functions such as transmission of measurement results, measured value storage management, measured value statistical analysis, and printing measured value reports to meet higher requirements of quality assurance activities and management;

u Work continuously for no less than 200 hours (when printing is not turned on), and power-saving functions such as automatic sleep, automatic shutdown, etc.;

Portable Richmond Hardness MeterTechnical parameters:

Measurement range: (170-960)HLD, (19-651)HB, (13.5-101.7)HRB, (17.9-69.5)HRC, (59.1-88)HRA, (80-1042)HV, (30.6~102.6)HS The measurement range can be customized for customers

Measurement direction: any (360°)

Applicable materials: steel and cast steel, alloy tool steel, stainless steel, grey cast iron, ductile iron, cast aluminum alloy, copper-zinc alloy (brass), copper-tin alloy (bronze), pure copper, forged steel

Display error and display repeatability: D-type impact device ±6HLD (demonstration error) ±6HLD (demonstration repeatability)

Hardness: 7 kinds of: Shore (HS), Richter (HL), Brechter (HB), Rockford (HRC/HRB/HRA), Vickers (HV), etc.

Upper and lower limit setting range: (170-960)HLD

Display calibration: It has display software calibration function

Data storage: 600 sets of measured values

Data interface: USB 2.0

Friendly links: