High and low temperature humidity and heat test chamber is a common component and component detection equipment. Before using the equipment, you need to be familiar with how to use the equipment safely to avoid causing harm to the equipment itself or personal safety.
The high and low temperature humidity and heat test chamber is used to test and determine the parameters and properties of electrical, electronic and other products and materials after temperature environment changes in high-temperature, low temperature, alternating, humid and heat or constant tests. It is the main force of the industry's products and has high operating requirements for the test chamber. In addition to standardized operation, there will be some misunderstandings in the operation of high and low temperature and humidity test chambers. This requires our operators to pay attention to:
![Some misunderstandings that may exist in operation of high and low temperature humidity and heat test chambers [Information]](http://www.hssdtest.com/uploads/image/20250418/76/3c7f937c604436bf1fdd35b8fa2cf7d8.jpg)
Misconception 1. The high and low temperature and humidity test chambers do not supply power to the standard and are reliably grounded; they ignore the guarantee of test chambers and personal safety;
Misconception 2: The sample to be tested is placed in the equipment work area, which requires careful browsing of the instructions on the instruction manual;
Misconception 3. If a heating sample is placed in the box, please use an external power supply and do not use the power supply of the device itself directly;
Misconception 4. When transporting products, be careful to avoid damaging vulnerable parts such as instruments on the panel. The inclination angle of products with refrigeration function shall not be greater than 45℃ when transporting. After the high and low temperature humidity and heat test chamber is placed in place, it should be left to stand for 1 to 2 days before turning on the machine, which is conducive to the normal operation of the refrigeration system after starting up and extending its life;
Misconception 5. When the temperature inside the high and low temperature humidity and heat test chamber is ≥55℃, please do not turn on the refrigeration compressor to ensure the normal operation of the compressor;
Misconception 6. Do not open/close the product box door with gravity, otherwise it will easily cause the box door to fall off, causing product damage, and causing unnecessary injury accidents;
Misconception 7. When the equipment is stopped for a long time, it should be regularly dispelled from moisture to avoid damaging the relevant devices;
Misconception 8. Do not open the box door or enter the box unless necessary during the test, otherwise it may cause personal injury and equipment misoperation;
Misconception 9: Non-professional personnel in high and low temperature and humidity test chambers shall not be disassembled or repaired.
The above is a related introduction to some misunderstandings that may exist in the operation of high and low temperature and humidity test chambers. I hope it can help you. If you want to know more detailed information about the test machine, you are welcome to follow our company. This not only provides you with high-quality test machine equipment, but also provides various equipment information to help you further understand the equipment. If you have any needs, please come and consult.