Maintenance of electronic universal testing machine

Release time:2018-11-23 source:Jinan Hengsi Shanda Instrument Co., Ltd. Browse:


Let me introduce it briefly nowUniversal testing machine(such as electronic universal testing machine, hydraulic universal testing machine) maintenance methods, users can read carefully. These are all experiences we have summarized in years of production and sales. First of all, the maintenance of the main machine includes the fixtures equipped with the machine should be coated with anti-rust oil for storage; the sliding surface of the inlay plate and the dovetail groove surface on the lining plate should be kept clean, and a thin layer of MoS2 grease should be applied regularly; 4. Regularly check the screws in the jaws, if they are loose, tighten in time; regularly check the transmission status of the sprocket, if they are loose, please re-tension the tensioner; since the jaws of the hydraulic universal testing machine are often used, which is easy to wear, and when there is too much oxide scale, it is easy to cause small piston damage and oil leakage, so the jaws should be cleaned frequently to keep them clean;

Now to introduce universal testing machine (such as electronicuniversal testing machine, hydroulic universal testing machine)maintenance method, the user can read carefully, this is all we are summarized in the years of production and sales experience, the first host machine maintenance fixture with should be coated with indian rust oil with steel plate and custody; liner contact sliding surface, lining the dovetail groove plate should be kept clean,grease MoS2 regularly coated with a thin layer of; screw 4, regularly check the jaw position, if found loose, timely tightening; regularly check the transmission chain, if found loose, please put the tensioner again tension because the hydroulic universal testing machine; jaw often use, easy to wear, oxidation easily lead to leakage of piston damage, so the jaw should be cleaned regularly, keep clean;

Secondly, the oil source must be well maintained. The control system regularly checks whether the connection wire of the rear panel of the controller is in good contact. If it is loose, it should be tightened in time. If it is not used for a long time after the test, turn off the controller and the computer; the interface on the controller corresponds one by one, and plugging in the wrong interface may cause damage to the equipment; the interface on the plug-in and unplugging the controller must turn off the power supply of the controller.

The second source of oil have good maintenance, regular inspection and control system controller connection panel is good contact, such as loose, should be tightened; after the test if along period of time than machine, close the controller and computer; controller on the interface of one one corresponding,inserted the wrong interface may cause damage to the equipment;plug controller interface must be shut down the power supply controller.