5-step process of low-temperature tank impact test machine

Release time:2018-11-23 source:Jinan Hengsi Shanda Instrument Co., Ltd. Browse:


Low temperatureImpact testing machineThe test has a perfect operating process, which can reduce operational errors to ensure the normal use of the product. The following is a brief introduction to low-temperature test operations by our company:


DWCThe series of low-temperature tanks are special auxiliary refrigeration equipment for low-temperature impact tests. The stacked compression mechanism is cold, and it uses imported high-reliability compressors, single-chip microcomputer control, automatic temperature control, automatic timing, automatic alarm, high temperature control accuracy, fast cooling speed and large volume; digital temperature display, safe and reliable, and easy to operate. Completely meet the national standardsGB/T229-2007Metallic Supi PendulumImpact test methodThe various temperature control indicators required for low-temperature devices in 》 are ideal sample cooling and insulation equipment in low-temperature impact tests of metal materials.



Low temperature tank operation process:



1.Liquid medium must be added to the low-temperature tank before use, otherwise the heater will be damaged when powered on, and the liquid level of the medium should be lower than the workbench plate30mmabout.



2.Alcohol or freezer is generally used for liquid media in the low-temperature tank.



3.After the low-temperature tank cooling switch is turned off, the refrigeration switch should be turned on again.10~20minute(Depending on the ambient temperature).



4.Low temperature tank power supply:220V50Hz, the power supply power should be greater than the total power of the instrument, and the power supply must have a good "grounding" device.



5.The low-temperature constant temperature tank should be placed in a dry and ventilated place, around the instrument300mmNo obstacles inside. When the working temperature of the low-temperature constant temperature tank is low, be careful not to enter the tank to prevent frostbite. After use, all switches are turned off and the power is cut off. The low-temperature constant temperature tank should be cleaned regularly to keep the work surface and operating panel clean.