Current location:front page >> Product Center >> Impact testing machine series >> Non-metallic material impact test machine
XJJ-5 simple supporting beam impact test machine

XJJ-5 simple supporting beam impact test machine
Product Classification: Non-metallic material impact test machine
Product Overview:The main technical parameters of the XJJ-5 simple supporting beam impact tester are fully in line with ISO 179, GB/T 1043, GB/T 2612, JB/T 8762, and GB4742 standards. Replace different energy impact pendulums and adjust the jaw seat to perform various impact tests. This machine is a detection instrument with reasonable structure, beautiful shape, convenient operation and accurate data. It is widel


Product Description:
The main technical parameters of the XJJ-5 simple supporting beam impact tester are fully in line with ISO 179, GB/T 1043, GB/T 2612, JB/T 8762, and GB4742 standards. Replace different energy impact pendulums and adjust the jaw seat to perform various impact tests. This machine is a detection instrument with reasonable structure, beautiful shape, convenient operation and accurate data. It is widely used in hard plastics, fiberglass, reinforced nylon and other fields.
Technical parameters: (The above parameters are for reference only, and the detailed parameters are mainly real equipment)
1. The pendulum energy, pendulum torque, and dial small index values are as follows:
Pendulum energy | 1J | 2J | 4J | 5J |
Pendulum torque | 0.516Nm | 1.031Nm | 2.062Nm | 2.578Nm |
Small index value of the scale disc | 0.01J | 0.02J | 0.04J | 0.05J |
2. Impact speed: 2.9m/s
3. Pre-raised angle of pendulum: 160°
4. The distance from the center of the swing shaft to the center of the sample: 221mm
5. Claw rounded corner radius: 1mm
6. Impact blade angle: 30°
7. Impact blade rounded corner radius: 2mm
Sample Type | Length L | Width b | Thickness d | Distance between support lines |
1 | 80±2 | 10±0.5 | 4±0.2 | 60 |
2 | 50±1 | 6±0.2 | 4±0.2 | 40 |
3 | 120±2 | 15±0.5 | 10±0.5 | 70 |
4 | 125±2 | 13±0.5 | 13±0.5 | 95 |
(The above parameters are for reference only, and the detailed parameters are mainly real equipment)
- Previous article:Bolt and nut test fixture
- Next article:XJJ-50 series simple supporting beam impact test machine
Recommended informationNEWS
- [2022-08-26]Do you know how important the configuration of the universal tensile test machine is? The configuration of the universal tensile test machine
- [2022-08-26]Introduction to the functions of the repeated bending test machine of metal material
- [2022-08-26]How to use the universal tensile testing machine?
- [2022-08-26]What are the key points of the lateral deformation test of electronic universal testing machines?
- [2022-08-12]Testing method of metal rods by testing machine
- [2022-08-12]Electronic universal testing machine-Plastic film tensile testing machine
- [2022-08-04]How to install a clamp to save effort
- [2022-08-04]What are the causes of oil leakage in the universal pressure test machine?
- [2022-08-04]Tension machine
- [2022-07-29]Staff must conduct necessary inspections on the different structures and parts of the fatigue testing machine
- [2022-07-29]In practical applications, friction between parts is inevitable.
- [2022-07-29]Methods to avoid positioning errors of electronic universal test machines
- [2022-07-29]What errors are prone to occur when using the fatigue test machine
- [2022-07-29]Performance characteristics of electronic universal testing machine and preparations before operation
- [2022-07-20]What are the safety and service life of the woven bag tensile tester?
- [2022-07-20]Several categories of tension machine sensors
- [2022-07-20]Calibration of universal testing machine sensor
- [2022-07-20]Introduction to technical problems of material tensile testing machine

















