Hello, welcome to visitJinan Hengsi Shanda Instrument Co., Ltd.
Some of you are interested in:
Coating thickness gauge HCT2610

Coating thickness gauge HCT2610

Product Classification: Roughness meter Thickness meter and other non-destructive testing equipment
Product Overview:This instrument complies with the following standards: GB/T 4956-1985 measurement of the thickness of non-magnetic cover layer on magnetic metal matrix, magnetic method; GB/T 4957-1985 measurement of the thickness of non-conductive cover layer on non-magnetic metal matrix, eddy current method. JB/T 8393-1996 Magnetic and eddy current cladding thickness measuring instrument JJG 889-95 "Magnetic Res

This instrument complies with the following standards: GB/T 4956-1985 measurement of the thickness of non-magnetic cover layer on magnetic metal matrix, magnetic method; GB/T 4957-1985 measurement of the thickness of non-conductive cover layer on non-magnetic metal matrix, eddy current method. JB/T 8393-1996 Magnetic and eddy current cladding thickness measuring instrument JJG 889-95 "Magnetic Resistance Thickness Meter" JJG818-93 "Eddy current Thickness Meter".

Features:

All-Chinese interface operation is more convenient;

This instrument adopts two methods of thickness measurement: magnetic and eddy current

Can be equipped with 7 types of probes F400, F1, F1/90°, F10, CN02, N1

495 measured values ​​can be stored;

Limits can be set: the measured values ​​outside the limit can be automatically alarmed; and a batch of measured values ​​can be analyzed using histograms;

LCD dot matrix LCD, LED backlight display;

It has the function of communicating with the PC: it can transmit measured values ​​and statistical values ​​to the PC for further processing of data;

It has an error prompt function, and error prompts are made through screen display or beeping;

There are two shutdown methods: manual shutdown method and automatic shutdown method.

TechniqueMeasurement parameters:

Measurement principle:Magnetic induction and eddy current

Probe connection method:Split wire connection (replaceable)

Temperature and humidity:0-40℃ 20%RH ~ 90%RH

Statistical function:Average value (MEAN), maximum value (MAX), minimum value (MIN), number of tests (NO.), standard deviation (S.DEV)

How to work:Direct method (DIRECT) and group method (Appl)

Measurement method:Continuous measurement method (CONTINUE) and single measurement method (SINGLE)

Upper and lower limit settings:have

Storage capability:495 measured values

Connect to a computer:Can connect to a computer

Shutdown method:Manual and automatic

power supply:AA (No. 5) battery

Friendly links: